Mobicon-Remote Electronic Pte Ltd
50 Ubi Ave 3,
#02-06 Frontier,
Singapore 408866.
+65-67477472
+65-67476768

DG308-2.54 PCB UNIVERSAL SCREW TERMINAL BLOCK

Previous 23 / 130 Next

DG308-2.54 PCB UNIVERSAL SCREW TERMINAL BLOCK PCB Universal Screw Terminal Blocks Terminal Blocks Degson
Quantity
Add Quotation


Item Data  
APPROVAL
Test standard IEC/EN60998-1£º2004 / UL1059
Pitch                                      [mm] 2.54
Poles 02-12P
EN60998 Test data VDE certificate NO. 40022178
Rated voltage                              [V] 130
Rated current                              [A] 8
Rated connection capacity(solid/stranded) [mm²] 0.5-1.0
Surge voltage category/pollution degree/material group III/2/I
Withstanding Voltage                  [KV/min] 1.25
Rated torque                               [N.m] 0.15
UL1059Test data UL File Number E228872
Use group B C D
Rated voltage                              [V] 150 / /
Rated current                              [A] 6 / /
Rated connection capacity 26~18
(solid/stranded) [AWG]
Rated torque                        [Lb. in] 1
General data /
Screw M1.6
Inflammability classUL94 V-0
Ambient temperature                        [¡æ] -40~+105
Relative humidity 5%-95%
Inspection standard MIL-STD-105E II
AQL 0.65
Warranty 12 months
Material and plating /
Housing PA66
Screws Steel£¬Zn plated
Contact Copper alloy £¬Sn plated
Cage Copper alloy£¬Ni Plated
Wire connecting
Recommended stripping length 4.5mm;
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.
Tightening process should be steady, can’t use explosive force.

You have 0 items in you cart. Would you like to checkout now?