Mobicon-Remote Electronic Pte Ltd
50 Ubi Ave 3,
#02-06 Frontier,
Singapore 408866.
+65-67477472
+65-67476768

Comet H6420 Temperature, humidity, CO2 transmitter with two relay and RS485 outputs

Previous 31 / 144 Next

Comet H6420 Temperature, humidity, CO2 transmitter with two relay and RS485 outputs Transmitters and Regulators Comet
Quantity
Add Quotation


Download Files

Cometsystem_H6420.pdf (0.97 MB)
code: H6420
Temperature, humidity, CO2 level sensor with two output relays.

Included in delivery:

 

  • H6420 sensor
  • Traceable calibration certificate
  • Quick start manual
  • Technical support at discussion forum

Transmitter is also equipped with three alarm LEDs:

Green LED shines - CO2 concentration 0 to 1000 ppm

Yellow LED shines - CO2 concentration 1001 to 1200 ppm

Red LED shines - CO2 concentration 1201 ppm and more

Technical parameters Value
Output RS485
Measured Value CO2 + Temperature + Relative Humidity
Construction Type Ambient Air
Design Industrial
Temperature Measuring Range -30 to 60 °C
Relay Output Yes
Two-State Input No
Lcd Display Yes
PoE No
Maximum switching voltage, current, power of relay output 50V, 2A, 60VA
Audible alarm from built-in beeper - switchable
Range of CO2 concentration measurement 0 to 2000ppm
Accuracy of CO2 concentration measurement ±(50ppm +2% from reading) at 25°C and 1013hPa
Optional range of CO2 concentration measurement 0 to 10000ppm ±(100ppm +5% from reading) at 25°C and 1013hPa
Relative humidity range 0 to 100%
Accuracy of relative humidity measurement ±2.5% relative humidity from 5 to 95% at 23°C
Accuracy of temperature output ±0.4°C
Available temperature units degrees Celsius, Fahrenheit
Accuracy and range of dew point temperature output - for more details see graphs ±1.5°C at ambient temperature T<25°C and RH>30%
range -60 to +80 °C
Accuracy and range of absolute humidity output ±1.5g/m3 at ambient temperature T < 25°C
range 0 to 400 g/m3
Accuracy and range of specific humidity output ±2g/kg at ambient temperature T < 35°C
range 0 to 550 g/kg
Accuracy and range of mixing ratio output ±2g/kg at ambient temperature T < 35°C
range 0 to 995 g/kg
Accuracy and range of specific enthalpy output ±3kJ/kg at ambient temperature T < 25°C
range: 0 to 995 kJ/kg
Measuring interval of CO2 15s
Temperature operating range -30 to +60°C
Filtering ability of sensor cover 0.025mm - filter with stainless steel mesh
Communication protocol ModBus RTU, ARION and Advantech ADAM compatible protocol
Communication speed 110 to 115200 Bd
IP protection IP30 electronics, IP40 sensors
Power 9-30Vdc, power consumption approximately 1W
Dimensions 136 x 213 x 45 mm (W x H x D), stem length 75 mm
Weight approximately 360g

Optional accessories

Description
AC/DC adapter 12V/450mA stabilized
plastic sensor protection with stainless filter (gray)
sintered bronze sensor cover
PTFE sensor protection, white
Tool for easy connection to WAGO terminals 233 for serial output transmitters
Vessel for adjustment and calibration of humidity
Humidity Standard 10%RH, set 5pcs
Humidity Standard 80%RH, set 5pcs
Converter USB/RS485 for MS5


You have 0 items in you cart. Would you like to checkout now?
0 items
Switch to Mobile Version
Recent Updates
Subscribe Newsletter
1
Hello! Thanks for visiting my site. Please press Start button to Contact with Admin :)

Start